2-156 TB 9-2510-251-13 34 34 34 35 35 35 36 36 37 37 32 2-2.1 Installation of Air Conditioning Kit to M998 and M998A1; M1037; M1097 and M1097A1 Two-Door with O’Gara Hess Add-on-Armor (Cont’d). b. Install Evaporator and Condenser (Cont’d) WARNING Use caution when drilling through floor not to damage or drill into the fuel tank. Failure to comply may cause injury or death to personnel or damage to equipment. Figure 2-233. Base Support Bracket (24) Square base support bracket (32) to floor. (25) Drill four 3/8 inch (.375) diameter holes, using condenser base support bracket as a guide. (26) Secure base support bracket (32) to floor with four bolts (33), washers (34), condenser support backing plates (35), washers (36), and locknuts (37). Tighten bolts. 33 33