2-155 TB 9-2510-251-13 2-2.1 Installation of Air Conditioning Kit to M998 and M998A1; M1037; M1097 and M1097A1 Two-Door with O’Gara Hess Add-on-Armor (Cont’d). b. Install Evaporator and Condenser (Cont’d) 18 20 19 21 21 29 27 28 24 22 22 23 25 26 26 23 30 30 31 Figure 2-231. Evaporator Unit Figure 2-232. Rear Armor (19) Position evaporator unit (18) in lower evaporator bracket (19) and loosely secure to bottom holes with two bolts (20). (20) Swing evaporator unit (18) into upright position and loosely secure to remaining upper and lower bracket holes with six bolts (21). (21) Remove existing bolts from Row 6 and Row 7. (22) From rear of armor, install two bolts (22), washers (23), and lower condenser bracket (24) in Row 6 and Row 7, and secure with washers (25) and locknuts (26). (23) Position condenser base support bracket (27) on lower condenser bracket (24) and loosely secure to two center holes in lower condenser bracket and base support bracket with two bolts (28), washers (29), washers (30), and locknuts (31).