TB-9-2510-251-13 HMMWV Operator and Field Maintenance, Installation & Parts Add-On-Armor Air Conditioning Download

Page 170 of 624

2-154 TB 9-2510-251-13 ROW 1 ROW 2 ROW 3 ROW 4 ROW 5 ROW 6 ROW 7 15 14 6 13 13 14 6 7 7 8 9 9 14 16 16 17 17 16 17 16 11 12 11 11 12 10 11 4 2-2.1 Installation of Air Conditioning Kit to M998 and M998A1; M1037; M1097 and M1097A1 Two-Door with O’Gara Hess Add-on-Armor (Cont’d). b. Install Evaporator and Condenser (Cont’d) Figure 2-230. Evaporator Brackets 5 (8) Position upper evaporator bracket (4) on rear armor plate. Line upper evaporator bracket (4) with Row 2 and Row 3 bolts. (9) Using upper evaporator bracket (4) as template, trace and cut insulation foam from bracket area. (10) Position lower evaporator bracket (5) on rear armor plate. Line upper evaporator bracket (5) with Row 4 and Row 5 bolts. (11) Using bracket (5) as a template, trace and cut insulation foam from bracket area. (12) Remove existing bolts from Row 4 and Row 5. (13) From rear of armor, install two bolts (6) and washers (7) in Row 4. Install two bolts (8) and washers (9) in Row 5. (14) Install shims (10) as required on Row 4. (15) Position lower evaporator bracket (5) on Row 4 and Row 5, and secure with washers (11) and locknuts (12). (16) Remove existing bolts from Row 2 and Row 3. (17) From rear of armor, install four bolts (13), washers (14), and upper condenser bracket (15) in Row 2 and Row 3. (18) Position upper evaporator bracket (4) on Row 2 and Row 3, and secure with washers (16) and locknuts (17).