TB-9-2510-251-13 HMMWV Operator and Field Maintenance, Installation & Parts Add-On-Armor Air Conditioning Download
Page 154 of 624
2-138 TB 9-2510-251-13 2-1.4 Installation of Air Conditioning Kit to M1025A2 with GSIE Add-on-Armor (Cont’d). d. Install Refrigerant Hoses (Cont’d) 18 19 17 20 Figure 2-209. Drier Connection 22 24 23 21 Figure 2-210. Condenser Connection (14) Connect Condenser. a. Lubricate O-ring and install #6 female straight fitting (21) to outlet (smaller) fitting on condenser. b. Lubricate O-ring and install #8 female straight fitting (22) to inlet (larger) fitting on condenser. c. Trim ends of #6 hose from drier (23) and connect to right fitting. d. Trim ends of #8 hose from compressor (24) and connect to right fitting. (15) Reinstall plywood panel on top of transmission tunnel by notching around drain hoses and refrigerant lines. (13) Connect Drier. a. Lubricate O-ring and install #6 male stainless tube (17) on drier outlet. b. Lubricate O-ring and install #6 female 90° fitting (18) on drier inlet. c. Trim ends of #6 hose (19) to condenser and connect to inlet (female) fitting. d. Trim ends of #6 hose (20) to evaporator and connect to outlet (male) fitting. e. Tighten fittings.