TB-9-2510-251-13 HMMWV Operator and Field Maintenance, Installation & Parts Add-On-Armor Air Conditioning Download

Page 140 of 624

2-124 TB 9-2510-251-13 2-1.4 Installation of Air Conditioning Kit to M1025A2 with GSIE Add-on-Armor (Cont’d). b. Install Evaporator and Condenser (Cont’d) (16) Insert four new bolts (14), flat washers (15), and oversize washers (16) through lower evaporator support bracket and armor plates. Install flat washers (17) and locknuts (18) and tighten snug. 18 17 15 16 14 Figure 2-190. Lower Support Bracket