TB-9-2510-251-13 HMMWV Operator and Field Maintenance, Installation & Parts Add-On-Armor Air Conditioning Download
Page 139 of 624
2-123 TB 9-2510-251-13 2-1.4 Installation of Air Conditioning Kit to M1025A2 with GSIE Add-on-Armor (Cont’d). b. Install Evaporator and Condenser (Cont’d) (10) Loosely attach upper clamp brackets (9) to upper support brackets (10) on evaporator unit (11) with four bolts (12), flat washers (13), and locknuts (14). 12 13 9 11 14 10 Figure 2-188. Clamp Brackets 13 13 13 13 12 11 Figure 2-189. Install Evaporator Unit (11) Remove two lower center 1/2 inch bolts from rear center armor plate and rear side armor plates. (12) Hang evaporator unit (11) from inside top of armor plate (above holes drilled in transmission tunnel). (13) Adjust evaporator unit (11) to align slots in lower support bracket (12) with slots in center armor plate. (14) Close hatch and check for handle interface with top of evaporator unit. (15) Tighten evaporator unit top clamp bracket bolts (13).