TB-9-2510-251-13 HMMWV Operator and Field Maintenance, Installation & Parts Add-On-Armor Air Conditioning Download

Page 126 of 624

2-110 TB 9-2510-251-13 2-1.4 Installation of Air Conditioning Kit to M1025A2 with GSIE Add-on-Armor (Cont’d). a. Install Compressor (Cont’d) Figure 2-166. Compressor Installation (15) Position compressor (18) on mounting bracket (19) and secure with bolt (20), washer (21), and locknut (22). Tighten bolt (20) to 18 ft-lbs. Do not overtighten. 19 21 22 18 20