TB-9-2510-251-13 HMMWV Operator and Field Maintenance, Installation & Parts Add-On-Armor Air Conditioning Download

Page 113 of 624

2-97 TB 9-2510-251-13 2-1.3 Installation of Air Conditioning Kit to M1025 and M1025A1 with GSIE Add-on-Armor (Cont’d). d. Install Refrigerant Hoses (Cont’d) Figure 2-145. Compressor Connection (11) Connect Compressor. a. Lubricate O-ring and install #8 female 45° or 90° fitting (8) on upper compressor connection. b. Lubricate O-ring and install #12 female 90° fitting (9) on lower compressor connection. c. Ensure hood of vehicle will close and air intake duct can be reinstalled over compressor. d. Trim ends of #8 (10) and #12 (11) hoses to length and connect to fittings. e. Tighten fittings. 9 11 8 10