TB-9-2510-251-13 HMMWV Operator and Field Maintenance, Installation & Parts Add-On-Armor Air Conditioning Download

Page 106 of 624

2-90 TB 9-2510-251-13 44 45 (33) Install electrical EMI filter panel (45) to plumbing end of condenser mount bracket (44). Panel (45) should be oriented so that the wiring is on the bottom. Secure with original hardware. (34) Fold and secure pressure switch wires onto condenser harness. (35) Open hatch. 46 46 2-1.3 Installation of Air Conditioning Kit to M1025 and M1025A1 with GSIE Add-on-Armor (Cont’d). b. Install Evaporator and Condenser (Cont’d) Figure 2-137. EMI Filter Panel Figure 2-138. Stiffener Hole (36) Drill a 3/8 inch (.375) hole (46) in outboard flange of stiffener, approximately one inch forward of gas shock pivot point on each side of hatch. (37) Place template on outside of hatch. (38) Align with forward edge and hole (46). (39) Drill six 3/8 inch (.375) mounting bolt holes. (40) Drill three 1 1/4 inch (1.250) hose/wire holes. (41) Position condenser assembly on rear hatch with wire harness and fitting on driver’s side of hatch. Secure with bolts, washers, and locknuts.