TB-9-2510-251-13 HMMWV Operator and Field Maintenance, Installation & Parts Add-On-Armor Air Conditioning Download

Page 105 of 624

2-89 TB 9-2510-251-13 41 40 43 42 43 42 2-1.3 Installation of Air Conditioning Kit to M1025 and M1025A1 with GSIE Add-on-Armor (Cont’d). b. Install Evaporator and Condenser (Cont’d) Figure 2-134. Support Brackets Removal Figure 2-135. Side Condenser Mount Plates Removal 44 44 Figure 2-136. Condenser Mount Brackets (30) Remove two screws (40) and support brackets (41). Discard support brackets (41). (31) Remove six screws (42) and side condenser mount plates (43). Discard side condenser mount plates (43). (32) Install two condenser mount brackets (44) and secure with existing hardware.