5-125 TB 9-2320-280-35-15 Figure 5-140. 40-56. Attach shrink tubing (117) and terminal lug (115) to NTDR positive power terminal (134). Secure to terminal board stud (99) with existing nut (116). 40-57. Attach shrink tubing (117) and terminal lug (115) to NTDR negative power terminal (124). Secure to terminal board stud (108) with existing nut (116). 40-58. Attach shrink tubing (117) and terminal lug (115) to EPLRS positive power terminal (133). Secure to terminal board stud (100) with existing nut (116). 40-59. Attach shrink tubing (117) and terminal lug (115) to EPLRS negative power terminal (123). Secure to terminal board stud (109) with existing nut (116). 40-60. Attach shrink tubing (117) and terminal lug (115) to lower SINCGARS positive power terminal (132). Secure to terminal board stud (101) with existing nut (116). 40-61. Attach shrink tubing (117) and terminal lug (115) to lower SINCGARS negative power terminal (122). Secure to terminal board stud (110) with existing nut (116). 40-62. Attach shrink tubing (117) and terminal lug (115) to front SINCGARS positive power terminal (131). Secure to terminal board stud (102) with existing nut (116). 40-63. Attach shrink tubing (117) and terminal lug (115) to front SINCGARS negative power terminal (121). Secure to terminal board stud (111) with existing nut (116). 40-64. Attach shrink tubing (117) and terminal lug (115) to DAGR positive power terminal (130). Secure to terminal board stud (103) with existing nut (116). 40-65. Attach shrink tubing (117) and terminal lug (115) to DAGR negative power terminal (120). Secure to terminal board stud (112) with existing nut (116). 40-66. Attach shrink tubing (117) and terminal lug (115) to white control cable positive terminal (128). Secure to terminal board stud (105) with existing nut (116). 40-67. Attach shrink tubing (117) and terminal lug (115) to black control cable negative terminal (118). Secure to terminal board stud (114) with existing nut (116). 40-68. Attach shrink tubing (117) and terminal lug (115) to upper SINCGARS positive power terminal (127). Secure to terminal board stud (106) with existing nut (116). 40-69. Attach shrink tubing (117) and terminal lug (115) to upper SINCGARS negative power terminal (125). Secure to terminal board stud (108) with existing nut (116). 40-70. Attach shrink tubing (117) and terminal lug (115) to solenoid to positive power terminal (129). Secure to terminal board stud (104) with existing nut (116). 40-71. Attach shrink tubing (117) and terminal lug (115) to shunt to negative terminal (126). Secure to terminal board stud (107) with existing nut (116). 40-72. Attach shrink tubing (117) and terminal lug (115) to solenoid to negative terminal (119). Secure to terminal board stud (113) with existing nut (116). 119 120 121 123 125 126 127 128 129 130 131 132 133 122 116 117 115 118 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 117. SHRINK TUBING – MS23053/4-302-0 – QTY. A/R 124 99 134