5-21 TB 9-2320-280-35-14 Section XIII. FBCB2 CABLES INSTALLATION 13-1. Connect W3 cable (11) from SIAD (13) to J3 connector (9) on FBCB2 processor (7). 13-2. Route W3P cable (5) from SIAD (13) to DAGR mount (6). 13-3. Connect W2 cable (12) to J4 connector (8) on FBCB2 processor (7) and J1 connector (15) on FBCB2 display unit (4). 13-4. Connect W1 cable (2) to J1 connector (10) on FBCB2 processor (7). Route W1 cable (2) to A4J2 connector (17). 13-5. Connect keyboard cable (14) to J2 connector (16) on FBCB2 display unit (4). 13-6. Route W1J1 cable (3) to SINCGARS mount (1). Figure 5-29. 1 2 3 4 7 8 10 2 11 12 13 ~ ~ 2. W1 CABLE – 866003-3 – QTY. 1 12. W2 CABLE – 881327-1 – QTY. 1 5 6 9 14 15 16 17