TB-9-2320-280-35-12 HMMWV Technical Bulletin Installation for EPLRS Network Manager Download
Page 132 of 162
TB 9-2320-280-35-12 5-104 47-32. Attach shrink tubing (35) and terminal lug (48) to SINCGARS power cables (49) and (50). Secure cables (49) and (50) to terminal board hole (51) in terminal board (32) with existing screw (34). 47-33. Attach shrink tubing (35) and terminal lug (48) to lower EPLRS power cables (52) and (53). Secure cables (52) and (53) to terminal board hole (54) with existing screw (34). 47-34. Attach shrink tubing (35) and terminal lug (48) to upper EPLRS power cables (55) and (57). Secure cables (55) and (57) to terminal board hole (56) with existing screw (34). 47-35. Attach shrink tubing (35) and terminal lug (48) to SINCGARS negative cables (58) and (59). Secure cables (58) and (59) to terminal board hole (60) with existing screw (34). 47-36. Attach shrink tubing (35) and terminal lug (48) to lower EPLRS negative cables (61) and (63). Secure cables (61) and (63) to terminal board hole (62) with existing screw (34). 47-37. Attach shrink tubing (35) and terminal lug (48) to upper EPLRS negative cables (65) and (66). Secure cables (65) and (66) to terminal board hole (64) with existing screw (34). 32 48 34 35 49 50 51 58 59 60 62 63 64 65 66 61 52 53 54 55 56 57 Figure 5-144. 48. TERMINAL LUG – CRS-DY-1010 – QTY. 6