TB-9-2320-280-35-12 HMMWV Technical Bulletin Installation for EPLRS Network Manager Download

Page 114 of 162

TB 9-2320-280-35-12 5-86 Section XLII. INVERTER CABLE INSTALLATION 42-1. Connect inverter ground wire (1) to multi-net rack (3) lower shelf with self-tapping screw (2). 42-2. Install positive inverter cable (4) and negative inverter cable (7) to inverter (6) with existing nuts (5). 42-3. Route inverter output cable (8) between inverter (6) and inverter side wall (9) and connect inverter output cable (8) to inverter (6). 1 2 4 3 5 6 8 7 ~ ~ 9 ~ Figure 5-122. 1. GROUND WIRE – P/O 806-1050 – QTY. 1 2. SELF-TAPPING SCREW – 9421073 – QTY. 1 4. INVERTER POSITIVE CABLE – A3265730 – QTY. 1 7. INVERTER NEGATIVE CABLE – A3265692 – QTY. 1 6 ~ Figure 5-123.