MWO-9-2330-390-25-1 HMMWV M1022A1 Dolly Set Positioning Tube Reinforcement Download

Page 36 of 54

MWO 9-2330-390-25-1 C-4 APPENDIX C: TOP AND BOTTOM BEAM AND HYDRAULIC LIFT CYLINDER REMOVAL / INSTALLATION (Con’t). Escaping hydraulic fluid under pressure can penetrate the skin, causing serious injury to personnel. Relieve pressure before disconnecting hydraulic lines and fittings. Tighten all connections before applying pressure. Keep hands and body away from pinholes and nozzles that eject hydraulic fluid under high pressure. Use a piece of cardboard or paper to search for leaks. If any hydraulic fluid is injected into the skin, it MUST be surgically removed within a few hours by a doctor familiar with this type of injury or gangrene may result. 11. Disconnect two hose assemblies (6) from straight connectors (5) at positioning cylinders (2) inside bottom beam (3). 12. Remove two straight connectors (5) and preformed packings (4) from positioning cylinders (2). Discard preformed packings. 13. With top beam (1) suitably supported, remove top beam with upper vertical positioning tubes from positioning cylinders (2) and bottom beam (3). 14. Remove two positioning cylinders (2) from bottom beam (3). Place positioning cylinders on a clean work surface. 15. Remove cotter pin (11), washers (10) and clevis pin (12) and detach bottom beam from suspension structure. Discard cotter pins only. Save washers and clevis pins for later use. 16. Place both top and bottom beams with associated positioning tubes aside as scrap.