MOS-94P Multiple Launch Rocket System (MLRS) Repairer M142 HIMARS Download
Page 80 of 188
e. Hoses and fluid lines. 2. Remove two screws four washers and two nuts securing U clamp to L Clamp where the cable bundle passes through the turret to the rear of the cage. 3. Remove two screws and washers securing L clamp to turret where the cable bundle passes through the turret to the rear of the cage. 4. Remove cable clamp securing ground strap. 5. Remove cage down limit switch from limit switch bracket. 6. Remove Jury Struts. 7. Manually Lower Cage. 8. Remove elevation resolver door assembly. 9. Scribe transducer shaft mounting brackets. 10. Remove the transducer shaft-mounting bracket. 11. Remove power harness door. a. Unlatch four studs securing power harness door assembly. b. Remove the door assembly. c. Unlatch and open right RP connector door. 12. Using cross tip screwdriver, perform the following. a. Unlatch stud securing harness trough door assembly, open door. b. Unlatch two studs securing wire harness door assembly, remove door assembly. c. Unlatch and open armor door and PDB door assembly. 13. Disconnect the following electrical connectors. a. W305, W306, and W81 from PNU. b. W305, W306, W307, and W318 from WIU. c. W340 and W14 from PDB. d. Remove all cable clamps and cable ties securing the W340, W14, W305, W306, W307, W318, and W81 to the cage structure. 3-50 1 October 2014