091-94P-1065 Replace the Intermediate Beam DANGER Follow all Danger warning in TMs WARNING Follow all warning in TMs CAUTION Comply with all unit/shop SOPs Conditions: Perform this task in a operational environment given an armored vehicle- mounted M270A1 rocket launcher; a faulty intermediate beam; DA Form 2404, Equipment Inspection and Maintenance Worksheet; one 94P MLRS repairer; one 13M MLRS crewmember to assist as required; a 94P shop set and tool kit, a manila rope; two 4-inch by 4-inch by 5-foot wood supports; a HEMTT wrecker and an operator; TM 9- 1055-647-13&P; TM 9-243, and a DA Pamphlet 750-8, The Army Maintenance Management System (TAMMS) Users Manual. Note: This task may be performed in a Chemical, Biological, Radiological, and Nuclear (CBRN) environment. Standards: The intermediate beam was replaced according to the applicable technical manuals. Perform this task without causing injury to self, other personnel, the environment, or damage to equipment. Special Condition: None Special Standards: None Special Equipment: Cue: None Note: None Performance Steps 1. Inspect the intermediate beam and correct any defects. Check the following items below: a. Bolts and nuts. b. Bearings and bushings. c. Components. 3-38 1 October 2014