MOS-94P Multiple Launch Rocket System (MLRS) Repairer M142 HIMARS Download
Page 32 of 188
Performance Steps 1. Perform a visual inspection of the elevation position monitor transducer and correct any defects. Check the following items below: a. Bolts and nuts. b. Bearings and bushings. c. Components. d. Electrical cables and connectors. e. Hoses and fluid lines. 2. Remove the faulty elevation position monitor transducer. a. Unlatch the four studs and remove door. b. Disconnect the electrical connector from the transducer connector J1. c. Loosen the left coupling clamp screw and the transducer shaft clamp screw. d. Slide the coupling away from transducer to clear the transducer shaft. e. Remove the four nuts, eight washers, and four bolts. f. Remove the elevation Position monitor transducer. 3. Install the elevation position monitor transducer. a. Position the elevation position transducer on LM. b. Install the four bolts, eight washers, and four nuts. c. Connect the electrical connector to the transducer connector J1. d. Check the alignment between the resolver shaft and the pivot bolts. e. Install the coupling. 4. Adjust the elevation position monitor transducer. 5. Verify the elevation position monitor transducer is operational. 6. Cycle the rocket launcher in elevation. 7. Complete maintenance forms. 3-2 1 October 2014