MOS-94P Multiple Launch Rocket System (MLRS) Repairer M142 HIMARS Download
Page 163 of 188
STP 9-94P1-SM-TG 091-94P-1215 Replace the Boom Extension Actuators DANGER Follow all Danger warning in TMs WARNING Follow all warning in TMs CAUTION Comply with all unit/shop SOPs Conditions: Perform this task in a operational environment given an M142 HIMARS Launcher; a faulty boom extension actuator; DA Form 2404, Equipment Inspection and Maintenance Worksheet; one 94P HIMARS repairer and one 13M MLRS crewmember to assist as required; a 94P shop set and tool kit; lock wire; TM 9-1055-1646-13&P; TM 9-243; DA Pamphlet 750-8, The Army Maintenance Management System (TAMMS) Users Manual. Note this task may be performed in a Chemical, Biological, Radiological, and Nuclear (CBRN) environment. Standards: The boom extension actuator is replaced according to the applicable technical manuals. Perform this task without causing injury to self, other personnel, the environment, or damage to equipment. Special Condition: None Special Standards: None Special Equipment: Cue: None Note: None Performance Steps 1. Inspect the boom extension actuator and correct any defects. a. Check bolts, nuts, and screws. b. Check bearings and bushings. c. Check components. d. Check electrical cables and connectors. e. Check hoses and fluid lines. 1 October 2014 3-133