MOS-94P Multiple Launch Rocket System (MLRS) Repairer M142 HIMARS Download

Page 161 of 188

STP 9-94P1-SM-TG 091-94P-1208 Replace the Limit Switches DANGER Follow all Danger warning in TMs WARNING Follow all warning in TMs CAUTION Comply with all unit/shop SOPs Conditions: Perform this task in a operational environment given an M142 HIMARS launcher; a faulty limit switch; DA Form 2404, Equipment Inspection and Maintenance Worksheet; one 94P HIMARS repairer and one 13M MLRS crewmember to assist as required; digital multi-meter; a 94P shop set and 94P tool kit; lock wire; TM 9-1055- 1646-13&P; TM 9-243, and DA Pamphlet 750-8, The Army Maintenance Management System (TAMMS) Users Manual. Note: This task may be performed in a Chemical, Biological, Radiological, and Nuclear (CBRN) environment. Standards: The limit switch is replaced according to the applicable technical manuals. Perform this task without causing injury to self, other personnel, the environment, or damage to equipment. Special Condition: None Special Standards: None Special Equipment: Cue: None Note: None Performance Steps 1. Inspect the limit switches and correct any defects. a. Check bolts, nuts, and screws. b. Check bearings and bushings. c. Check components. d. Check electrical cables and connectors. 2. Deploy the jury struts. 1 October 2014 3-131