TM-9-2320-334-13&P LHST Operator, Field and Parts Manual M1147A1 Trailer Download
Page 863 of 1184
TM 9-2330-334-13&P FLATRACK, AIR CHAMBER, and LOCK REPLACEMENT - CONTINUED 0107 00 0107 00-11 Change 1 INSTALLATION - Continued WARNING Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. To avoid injury or death, keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. NOTE • LH air chamber has tee fittings. • RH air chamber has 90-degree fittings. • LH air chamber is shown. 3. Apply sealing compound to threads of adapter fitting (25) and tee fittings (9 and 11). 4. Install adapter fitting (25) in air chamber (19). 5. Install tee fitting (11) in adapter fitting (25). 6. Install tee fitting (9) in air chamber (19).