TM-9-2320-334-13&P LHST Operator, Field and Parts Manual M1147A1 Trailer Download

Page 429 of 1184

TM 9-2330-334-13&P CIRCUIT BREAKER, MODULE, 0057 00 AND CONNECTOR REPLACEMENT - Continued 0057 00-11 Change 1 24 VDC CONNECTOR REMOVAL NOTE All 24 VDC connector wires are removed the same way. Tag wires and connection points prior to disconnecting. 1. Remove wire (31) from ground pin on 24 VDC connector (19). 2. Perform the previous step on remaining wires. 3. Remove four nuts (32), lockwashers (33), screws (34), cover (35), and 24 VDC connector (19) from voltage converter box cover (30). Discard lockwashers.