TM-9-2320-334-13&P LHST Operator, Field and Parts Manual M1147A1 Trailer Download
Page 426 of 1184
TM 9-2330-334-13&P CIRCUIT BREAKER, MODULE, 0057 00 AND CONNECTOR REPLACEMENT - Continued Change 1 0057 00-8 MODULE INSTALLATION - Continued 2. Strip approximately 1/4 in. (0.6 cm) of insulation from wire (18). 3. Solder wire (18) to pin E on 24 VDC connector (19). 4. Position wire (17) at position BRN on 12 VDC connector (16). 5. Tighten screw (15) at position BRN on 12 VDC connector (16). 6. Install wire (13) on right ground stud (14) with lockwasher (12) and nut (11). 7. Install wire (9) on circuit breaker CB7 “BAT” terminal stud (10) with lockwasher (8) and nut (7).