TM-9-2320-334-13&P LHST Operator, Field and Parts Manual M1147A1 Trailer Download
Page 425 of 1184
TM 9-2330-334-13&P CIRCUIT BREAKER, MODULE, 0057 00 AND CONNECTOR REPLACEMENT - Continued 0057 00-7 Change 1 MODULE INSTALLATION NOTE • This task shows locations of voltage converter box module wiring connection points. Refer to Table 2. Voltage Converter Box Module Wiring Connections for details. • Modules 1 through 5 are installed the same way, Module 3 shown. • Install plastic cable ties and convoluted tubing as required. Table 2. Voltage Converter Box Module Wiring Connections. MODULE CONNECTION POINTS 1 CB3, left ground stud, Position 2BL-12 VDC connector, E-Pin-24 VDC connector 2 CB4, left ground stud, Positions 4RED/ 5GRN-12 VDC connector, J-Pin-24 VDC connector 3 CB7, right ground stud, Position 6BRN-12 VDC connector, E pin –24 VDC connector 4 CB8, right ground stud, Positions 3YEL/ 4RED-12 VDC connector, B-Pin-24 VDC connector 5 CB1, right ground stud, Positions 7BLU/ 4RED-12 VDC connector, B-/J-/K-Pins-24 VDC connector 1. Install module (23) in voltage converter box (24) with three screws (22), lockwashers (21), and nuts (20).