TM-9-2320-334-13&P LHST Operator, Field and Parts Manual M1147A1 Trailer Download
Page 422 of 1184
TM 9-2330-334-13&P CIRCUIT BREAKER, MODULE, 0057 00 AND CONNECTOR REPLACEMENT - Continued Change 1 0057 00-4 MODULE REMOVAL NOTE • This task shows locations of Voltage converter box module wiring connection points. Modules 1 through 5 are removed the same way, Module 3 is shown. Refer to Table 1. Voltage Converter Box Module Wiring Connections for details. • Tag wires and connection points prior to disconnecting. • Remove plastic cable ties and convoluted tubing as required. 1. Remove nut (7), lockwasher (8), and wire (9) from circuit breaker CB7 “BAT” terminal stud (10). Discard lockwasher. 2. Remove nut (11), lockwasher (12), and wire (13) from right ground stud (14). Discard lockwasher. Table 1. Voltage Converter Box Module Wiring Connections. MODULE CONNECTION POINTS 1 CB3, left ground stud, Position 2BL-12 VDC connector, E-Pin-24 VDC connector 2 CB4, left ground stud, Positions 4RED/ 5GRN-12 VDC connector, J-Pin-24 VDC connector 3 CB7, right ground stud, Position 6BRN-12 VDC connector, E pin –24 VDC connector 4 CB8, right ground stud, Positions 3YEL/ 4RED-12 VDC connector, B-Pin-24 VDC connector 5 CB1, right ground stud, Positions 7BLU/ 4RED-12 VDC connector, B-/J-/K-Pins-24 VDC connector