TM-9-2320-366-34-4 MTV Direct Maintenance Manual M1083 Series - Volume 4 Download

Page 514 of 796

TM 9-2320-366-34-4 26-13. M1089 OUTRIGGER EXTENSION CYLINDER REPAIR (CONT) (5) Remove seal (8) from rod (7). Discard seal. (6) Remove ring (6) and cylinder head (9) from rod (7). (7) Remove wiper ring (10) from ring (6). Discard wiper ring. (8) Remove seal (11), back-up ring (12), preformed packing (13), two wear rings (14), and buffer seal (15) from cylinder head (9). Discard seal, back-up ring, preformed packing, wear rings, and buffer seal. (9) Perform steps (4) through (8) on remaining rod. b. Cleaning/Inspection. WARNING Dry Cleaning Solvent is TOXIC and flammable. Wear protective goggles and gloves; use only in well-ventilated area; avoid contact with skin, eyes, and clothes, and do not breath vapors. Keep away from heat or flame. Never smoke when using solvent; the flashpoint for Type I Dry Cleaning Solvent is 100°F (38°C) and for Type II is 138°F (50°C). Failure to comply may result in serious injury or death to personnel. If personnel become dizzy while using cleaning solvent, immediately get fresh air and medical help. If solvent contacts skin or clothes, flush with cold water. If solvent contacts eyes, immediately flush eyes with water and get immediate medical attention. Failure to comply may result in serious injury or death to personnel. (1) Clean all metal parts with dry cleaning solvent. 26-80