TM 9-2320-366-34-4 (13) Remove buffer seal (16), rod seal (17), and wiper ring (18) from cylinder head (12). Discard wiper ring, rod seal, and buffer seal. (14) Remove two wear rings (19) from cylinder head (12). Discard wear rings. (15) Remove check valve (20) from rod (3). (16) Remove three back-up rings (21) and preformed packings (22) from check valve (20). Discard preformed packings and back-up rings. (17) Remove cartridge holding valve (23) from rod (3). (18) Remove three back-up rings (24) and preformed packings (25) from cartridge holding valve (23). Discard preformed packings and back-up rings. b. Cleaning/Inspection. WARNING Dry Cleaning Solvent (P-D-680) is TOXIC and flammable. Wear protective goggles and gloves; use only in well ventilated area; avoid contact with skin, eyes, and clothes, and do not breathe vapors. Keep away from heat or flame. Never smoke when using solvent; the flashpoint for Type I Dry Cleaning Solvent is 100°F (38°C) and for Type II is 130°F (50°C). Failure to comply may result in serious injury or death to personnel. If personnel become dizzy while using cleaning solvent, immediately get fresh air and medical help. If solvent contacts skin or clothes, flush with cold water. If solvent contacts eyes, immediately flush eyes with water and get immediate medical attention. Failure to comply may result in serious injury or death to personnel. 26-75