TM-9-2320-366-34-4 MTV Direct Maintenance Manual M1083 Series - Volume 4 Download
Page 446 of 796
TM 9-2320-366-34-4 26-12 Change 2 26-2. M1089 THREE STAGE HYDRAULIC PUMP REPAIR (CONT) (34) Install port end cover (35) on third stage gear housing (33) with matchmarks aligned. (35) Position four washers (39) and nuts (40) on port end cover (35). (36) Tighten nuts (40), in 10 lb-ft increments, to 200 lb-ft (271 N•m) in sequence shown. (36.1) Position two washers (4) and nuts (3) on port end cover (1). End of Task. CAUTION Driven shaft must be turned during tightening of port end cap nuts to ensure no binding occurs. Driven shaft must turn freely after nuts have been fully tightened. Failure to comply may result in damage to equipment. NOTE Hydraulic pump manufactured prior to February 2001 will have one washer and nut on four corners of port end cover. NOTE Hydraulic pump manufactured after February 2001 will have two additional washers and nuts on one side of port end cover.