Page 284 of 796

TM 9-2320-366-34-4 21-7. P3 PLANETARY CARRIER MODULE REPAIR (CONT) WARNING Use care when installing retaining rings. Retaining rings are under tension and can act as projectiles when released. Failure to comply may result in injury to personnel. (4) Install indexing ring (7) and retaining ring (8) in planetary carrier (2). d. Follow-On Maintenance. Assemble transmission (para 21-2). End of Task. 21-42