TM 9-2320-366-34-4 21-5. CONVERTER HOUSING MODULE REPAIR (CONT) (6) Measure inside diameter of bushing (4), maximum inside diameter 2.962 in. (7.523 cm). (7) Inspect converter housing (5) for cracks, burrs, scoring, and grooves. (8) Inspect two bearings (6) for flat spots, scoring, grooves, nicks, burrs, and discoloration. c. Assembly. (1) Install preformed packing (1) on engine speed sensor (2). (2) Install engine speed sensor (2), retainer clip (3), and screw (4) in converter housing (5). (3) Install vent plug (6) in converter housing (5). NOTE Perform steps (4) through (6) if replacing a six splined drive hub and gear with a two splined drive hub and gear. (4) Replace cycloidal gear PN 23049376 and gear bushing PN 6881926 with cycloidal gear PN 29514537 and gear bushing PN 29514538 (para 20-3). (5) Replace pump housing PN 29502322 with pump housing PN 29514801, ball PN 145651, spring PN 29507709, and pin PN 29516030 (para 20-3). (6) Replace converter pump PN 29503570 or 29511380 with converter pump PN 29514788 (para 7-14). (7) Install two bearings (7) on gear (8). 21-34