TM 9-2320-366-34-4 Change 2 18-91 (80) Apply sealant to threads of four screws (98). (81) Install Power Distribution Panel (99) on support legs (73) with four washers (100) and screws (98). Refer to Table 18-1 for hole locations. (82) Position PLGR/M42 Alarm Plate (101) on support legs (73) with four washers (102), screws (103), and self-locking nuts (104). (83) Tighten four self-locking nuts (104) to 110-112 lb-in (12-14 N•m). (84) Apply sealant to threads of 12 screws (105). (85) Install top rear wall (106) and front head pad brace (107) on support legs (73) with four washers (108) and screws (105). Refer to Table 18-1 for hole locations. (86) Install Sincgars Shelf (109) on support legs (73) with four washers (110) and screws (105). Refer to Table 18-1 for hole locations. (87) Apply sealant to threads of two screws (111). (88) Install head pad (112) on front head pad brace (107) with two washers (113) and screws (111). WARNING Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel.