TM-9-2320-366-34-4 MTV Direct Maintenance Manual M1083 Series - Volume 4 Download
Page 128 of 796
TM 9-2320-366-34-4 18-6. 200 AMP ALTERNATOR REPAIR (CONT) (35) Position terminal lugs (49 and 50), washer (51), and lockwasher (52) on 12 vdc post (3) with screw (53). (36) Tighten screw (53) to 80 lb-in. (9 N·m). (37) Apply sealing compound to screw (53), lockwasher (52), washer (51), and terminal lugs (49 and 50). (38) Position terminal lugs (54 and 55), washer (56), and lockwasher (57) on 24 vdc post (8) with screw (58). (39) Tighten screw (58) to 80 lb-in. (9 N·m). WARNING Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (40) Apply sealing compound to screw (58), lockwasher (57), washer (56), and terminal lugs (55 and 54). Change 1 18-74