TM-9-2320-366-34-3 MTV Direct Maintenance Manual M1083 Series - Volume 3 Download

Page 840 of 1178

TM 9-2320-366-34-3 16-93. POWER TAKE-OFF (PTO) REPLACEMENT/REPAIR (CONT) NOTE Perform steps (29.1) through (29.3) on PTO Assembly (P/N 12378814-001). (29.1) Remove idler shaft (41) from housing (5). (29.2) Remove preformed packing (42) from idler shaft (41). Discard preformed packing. (29.3) Remove input gear (43), two thrust washers (44), and bearings (45) from housing (5). (30) Remove needle bearing (46) from housing (5). c. Cleaning/Inspection. WARNING Dry Cleaning Solvent (P-D-680) is TOXIC and flammable. Wear protective goggles and gloves; use only in well ventilated area; avoid contact with skin, eyes, and clothes, and do not breathe vapors. Keep away from heat or flame. Never smoke when using solvent; the flashpoint for Type I Dry Cleaning Solvent is 100°F (38°C) and for Type II is 130°F (50°C). Failure to comply may result in serious injury or death to personnel. If personnel become dizzy while using cleaning solvent, immediately get fresh air and medical help. If dry cleaning solvent contacts skin or clothes, flush with cold water. If dry cleaning solvent contacts eyes, immediately flush eyes with water and get immediate medical attention. Failure to comply may result in injury to personnel. 16-576 Change 1