TM-9-2320-366-34-3 MTV Direct Maintenance Manual M1083 Series - Volume 3 Download
Page 791 of 1178
TM 9-2320-366-34-3 (17) Disconnect test cable (5) from pressure transducer (4). (18) Remove pressure transducer (4) from adapter (3). (19) Disconnect hose (1) from adapter (3). (20) Remove adapter (3) from tee fitting (2). (21) Connect hose (1) to tee fitting (2). (22) Tighten hose (1) to 36-39 lb-ft (49-53 N·m). (23) Perform steps (1) through (22) for right side pilot pressure. NOTE Left and right side monoblock valve flow controls are adjusted the same way. Left side shown. (24) Loosen locking nut (7) on monoblock valve adjustment screw (8). CAUTION Do not overtighten monoblock valve adjusting screw. Failure to comply may result in damage to equipment. (25) Position monoblock valve adjustment screw (8) in monoblock valve (9) until monoblock valve adjusting screw (8) contacts valve seat (10). (26) Loosen monoblock valve adjustment screw (8) one quarter turn. (27) Hold monoblock valve adjustment screw (8) in position. (28) Tighten locking nut (7) on monoblock valve adjustment screw (8). (29) Perform steps (24) through (28) for monoblock valve right adjustment. 16-533