TM-9-2320-366-34-3 MTV Direct Maintenance Manual M1083 Series - Volume 3 Download
Page 787 of 1178
TM 9-2320-366-34-3 (31) Install three preformed packings (26) on 90-degree fitting (27). (32) Position 90-degree fitting (27) in monoblock valve (4). (33) Tighten 90-degree fitting (27) to 36-39 lb-ft (49-53 N·m). (34) Install three preformed packings (28) on fittings (29). (35) Position three fittings (29) in monoblock valve (4). (36) Tighten three fittings (29) to 109-114 lb-ft (148-155 N·m). d. Installation. WARNING Adhesive Sealant MIL-S-46163 can damage your eyes. Wear safety goggles when using; avoid contact with eyes. If sealant contacts eyes, flush eyes with water and get immediate medical attention. Failure to comply may result in injury to personnel. (1) Apply sealing compound to threads of four screws (1). (2) Position monoblock valve (2) on mounting plate (3) with four lockwashers (4) and screws (1). (3) Tighten four screws (1) to 33-37 lb-ft (45-50 N·m). 16-529