TM-9-2320-366-34-3 MTV Direct Maintenance Manual M1083 Series - Volume 3 Download
Page 751 of 1178
TM 9-2320-366-34-3 Change 2 16-507 (61) Install two preformed packings (81) on plugs (82). (62) Position two plugs (82) on upper control valve assembly (27). (62.1) Tighten two plugs (82) to 112-123 lb-ft (152-167 N•m) (62.2) Install preformed packing (82.1) on plug (82.2). (62.3) Position plug (82.2) in upper control valve assembly (27). (62.4)Tighten plug (82.2) to 68-75 lb-ft (92-102 N•m). e. Installation. (1) Place upper control valve assembly (1) in control panel (2). (2) Connect two air tubes (3) to upper control valve assembly (1). (3) Install upper control valve assembly (1) in control panel (2) with three bolts (4), six washers (5), and three nuts (6).