TM-9-2320-366-34-3 MTV Direct Maintenance Manual M1083 Series - Volume 3 Download

Page 729 of 1178

TM 9-2320-366-34-3 Change 2 16-500.1 (7) Install preformed packing (6) on adapter (7). (8) Position adapter (7) on linear directional control valve (3). (9) Tighten adapter (7) to 43-47 lb-ft (58-63 N•m). (10) Install tee fitting (8) on adapter (7). (11) Install two preformed packings (9) on 90-degree fittings (10). (12) Install two 90-degree fittings (10) on linear directional control valve (3). d. Installation. (1) Remove insulation on four wires (.1). (2) Position sleeving (.2) on four wires (.1) (3) Install splices (.3) between wires (.1) (4) Install sleeving (.2) on four wires (.1) CAUTION Removal of insulation from electrical wires conductors shall be performed so that there is no evidence of physical damage to individual strands. Failure to comply may result in damage to equipment. NOTE Remove ¼” of insulation from wires.