TM 9-2320-366-34-3 f. Adjustment. NOTE Left and right 30K winch relief valves are adjusted the same way. Left side shown. (1) Disconnect hose (1) from fitting (2). (2) Install plug (3) in hose (1). (3) Install reducer (4) on fitting (2). WARNING Use care in placement of STE/ICE-R instruments used to perform these adjustments. Hydraulic system pressures are approximately 3000 PSI. Hoses will move or jump under this pressure. Secure test instruments, as required. Failure to comply may result in injury to personnel or damage to equipment. (4) Connect test hose (5) to reducer (4). (5) Install 10,000 PSI transducer on test hose (5). (6) Connect 10,000 PSI transducer to STE/ICE-R. (7) Open hydraulic reservoir supply valve and return valve (TM 9-2320-366-10-2). (8) Start engine (TM 9-2320-366-10-1). (9) Position PTO switch to ON (TM 9-2320-366-10-1). (10) Increase engine speed to 1250-1450 RPM (TM 9-2320- 366-10-1). Change 1 16-391