TM-9-2320-366-34-3 MTV Direct Maintenance Manual M1083 Series - Volume 3 Download
Page 577 of 1178
TM 9-2320-366-34-3 WARNING Adhesive Sealant MIL-S-46163 can damage your eyes. Wear safety goggles when using; avoid contact with eyes. If sealant contacts eyes, flush eyes with water and get immediate medical attention. Failure to comply may result in injury to personnel. (4) Apply sealing compound to threads of screws (8). (5) Install manual override valve (7) and valve bracket (9) on control panel (10) with two screws (8), four washers (11) two lockwashers (12), and two nuts (13). (6) Connect hydraulic hoses (14 and 15) to manual override valve (7). (7) Connect electrical connector O (16) to manual override valve (7). c. Follow-On Maintenance. (1) Place hydraulic reservoir supply valve and return valve in open position (TM 9-2320-366-10-2). (2) Connect batteries (TM 9-2320-366-20-3). (3) Operate MHC and check for hydraulic leaks at manual override valve (TM 9-2320-366-10-2). End of Task. 16-341