TM-9-2320-366-34-3 MTV Direct Maintenance Manual M1083 Series - Volume 3 Download
Page 574 of 1178
TM 9-2320-366-34-3 16-60. M1089 TWO WAY SOLENOID VALVE REPLACEMENT (CONT) WARNING Adhesive Sealant MIL-S-46163 can damage your eyes. Wear safety goggles/glasses when using; avoid contact with eyes. If sealant contacts eyes, flush eyes with water and get immediate medical attention. Failure to comply may result in injury to personnel. (4) Apply sealing compound on threads of screws (8). (5) Install two way solenoid valve (7) on control panel (9) with two screws (8), four washers (10), two lockwashers (11), and nuts (12). (6) Connect hydraulic tubes (13 and 14) to two way solenoid valve (7). (7) Connect electrical connector (15) to two way solenoid valve (7). c. Follow-On Maintenance. (1) Place hydraulic reservoir supply valve and return valve in open position (TM 9-2320-366-10-2). (2) Connect batteries (TM 9-2320-366-20-3). (3) Operate MHC and check for hydraulic leaks at Two Way Solenoid Valve (TM 9-2320-366-10-2). End of Task. 16-338