TM-9-2320-366-34-3 MTV Direct Maintenance Manual M1083 Series - Volume 3 Download
Page 453 of 1178
TM 9-2320-366-34-3 (4) Place drain pan under erection cylinder (7). CAUTION Cap or plug hydraulic connections and connection points to prevent contamination of hydraulic system. Failure to comply may result in damage to equipment. NOTE Tag hydraulic connections and connection points prior to disconnecting. (5) Disconnect two hydraulic hoses (8) from erection cylinder (7). WARNING Erection cylinder weighs approximately 70 lbs (32 kgs). Attach suitable lifting device prior to removal. Failure to comply may result in injury to personnel or damage to equipment. NOTE Steps (6) through (8) require the aid of an assistant. (6) Remove screw (9), washer (10), and bushing (11) from rivet eyebolt (12). (7) Remove rivet eyebolt (12) from pivot shaft (13). (8) Remove pivot shaft (13) from erection cylinder (7). (9) Remove erection cylinder (7) from mast (14). 16-217