TM 9-2320-366-34-2 7-6. TRANSMISSION RESILIENT MOUNT AND BRACKET REPLACEMENT (CONT) (9) Remove two bolts (19) and resilient mount (20) from bracket (18). b. LH Installation. (1) Position resilient mount (1) on bracket (2) with two bolts (3). (2) Tighten two bolts (3) to 76-94 lb-ft (103-127 N·m). NOTE Steps (3) through (8) require the aid of an assistant. (3) Position bracket (2) on frame rail (4) with bolt (5) and self-locking nut (6). (4) Position bolt (7) and self-locking nut (8) in frame rail (4). (5) Tighten self-locking nuts (6 and 8) to 210-225 lb-ft (285-305 N·m). 7-50