TM 9-2320-366-34-2 CAUTION Ensure dial indicator lever is in contact with end face of rack bar. Failure to comply may result in faulty reading. (6) Firmly push rack head (6) of fuel injector (7) toward fuel injector until rack stop (8) contacts fuel injector base (9). NOTE No. 1 fuel injector is now in fuel shutoff position. (7) Hold rack head (6) in shutoff position and adjust dial indicator group until all dials read zero. (8) Tighten dial indicator group and release rack head (6). (9) Remove clip (10) from adapter sleeve (11) between fuel governor (12) and inlet manifold (13). (10) Slide sleeve (11) from fuel governor (12) toward cylinder head (3). (11) Install insertion tool into link pin (14) of output shaft (15). NOTE When properly installed, equal lengths of small diameter of insertion tool will extend from both ends of link pin. (12) Install holding tool between adapter sleeve (11) and small diameter of insertion tool. (13) Push holding tool down until small diameter of insertion tool contacts face of fuel governor (12). This is fuel setting measurement position. 4-13