TM-9-2320-366-34-2 MTV Direct Maintenance Manual M1083 Series - Volume 2 Download

Page 119 of 1434

TM 9-2320-366-34-2 (131) Position coolant fill hose (176) on hose fitting (177) with clamp (178). (131.1) Tighten clamp (178) to 34-44 lb-in. (4-5 N·m). CAUTION Ensure hoses and connection points are tagged correctly prior to disconnecting. Failure to comply may result in air system not being able to pressurize. (132) Connect two unloader valve hoses (179) to adapters (34). (133) Connect air compressor pressure hose (180) to 90- degree fitting (35). (134) Install air compressor intake hose (181) on 45-degree fitting (182) with clamp (183). (135) Install coolant bypass hose (184) on coolant tube (31) with clamp (185). Change 1 3-53