TM-9-2320-366-34-2 MTV Direct Maintenance Manual M1083 Series - Volume 2 Download

Page 1011 of 1434

TM 9-2320-366-34-2 a. Removal. CAUTION Cap or plug hoses and connection points to prevent contamination of hydraulic system. Failure to comply may result in damage to equipment. NOTE • Tag hoses and connection points prior to disconnecting. • Remove plastic cable ties as required. (1) Disconnect hose (1) from fitting (2). (2) Disconnect hose (3) from fitting (2). (3) Disconnect hose (4) from fitting (5). (4) Disconnect hose (6) from fitting (5). (5) Remove nuts (7 and 8) and fittings (2 and 5) from subframe (9). (6) Remove self-locking nut (10), clamps (11 and 12), and screw (13) from subframe (9). Discard self-locking nut. (7) Remove two self-locking nuts (14), clamps (15), and screws (16) from subframe (9). Discard self-locking nuts. 13-351