TM-9-2320-366-34-1 MTV Direct Maintenance Manual M1083 Series - Volume 1 Download
Page 898 of 1591
TM 9-2320-366-34-1 Change 1 2-753 CONTINUITY TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to adapter cable 31-pin connector pin A. (3) Connect negative (-) probe of multimeter to adapter cable 24-pin connector pin A2 and note reading on multimeter. (4) If continuity is not present, replace transmission adapter cable assembly (para 6-8). (5) Connect positive (+) probe of multimeter to adapter cable 31-pin connector pin A. (6) Connect negative (-) probe of multimeter to all other pins in adapter cable 31-pin connector and note reading on multimeter. (7) Connect negative (-) probe of multimeter to ground and note reading on multimeter. (8) If continuity is present, transmission adapter cable assembly is shorted; replace transmission adapter cable assembly (para 6-8). (9) Connect connector P67 to adapter cable 31-pin connector.