TM-9-2320-366-34-1 MTV Direct Maintenance Manual M1083 Series - Volume 1 Download
Page 804 of 1591
Change 1 2-659  TM 9-2320-366-34-1  CONTINUITY TEST  (1) Set multimeter to ohms.  (2) Connect positive (+) probe of multimeter  to adapter cable 31-pin connector pin X.  (3) Connect negative (-) probe of multimeter  to adapter cable 24-pin connector pin C3  and note reading on multimeter.  (4) If continuity is not present, replace  transmission adapter cable assembly  (para 6-8).  (5) Connect positive (+) probe of multimeter  to adapter cable 31-pin connector pin X.  (6) Connect negative (-) probe of multimeter  to all other pins in adapter cable 31-pin  connector and note reading on multimeter.  (7) Connect negative (-) probe of multimeter  to ground and note reading on multimeter.  (8) If continuity is present, transmission  adapter cable assembly is shorted; replace  transmission adapter cable assembly  (para 6-8).