Change 1 2-615 TM 9-2320-366-34-1 RESISTANCE TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to pin 1 of transmission turbine speed sensor. (3) Connect negative (-) probe of multimeter to pin 2 of transmission turbine speed sensor and note reading on multimeter. (4) If resistance is less than 200 ohms or greater than 400 ohms, replace transmission turbine speed sensor (para 6-5). (5) If resistance is between 200-400 ohms, replace WTEC III transmission ECU (TM 9-2320-366-20-4). (6) Connect internal wiring connector TSS to turbine speed sensor. (7) Install cover on control valve module with four screws. (8) Install control valve module (para 7-10). (9) Connect connector P67 to adapter cable 31-pin connector. (10) Connect batteries (TM 9-2320-366-20-3).