Page 460 of 1591
TM 9-2320-366-34-1  Change 1 2-321  RESISTANCE TEST  CAUTION  NOTE  Use care when testing electrical connectors.  Do not damage connector pins or sockets  with multimeter probes. Failure to comply  may result in damage to equipment.  Inspect connector pins/sockets for damage,  corrosion, and serviceability. Check that  connector pins are not pushed back and  are capable of making good contact.  (1) Set multimeter to ohms.  (2) Connect positive (+) probe of multimeter  to E solenoid connector pin A.  (3) Connect negative (-) probe of multimeter  to E solenoid connector pin B and note  reading on multimeter.  (4) If resistance is less than 2.5 ohms or  greater than 5.0 ohms, replace  E solenoid (para 7-7).  (5) If resistance is between 2.5-5.0 ohms,  replace WTEC II TEPSS (TM 9-2320-366-  20-4).  (6) Connect internal wiring harness connector E  to E solenoid connector.  (7) Install cover on control valve module with  four screws.  (8) Install control valve module (para 7-10).  (9) Connect batteries (TM 9-2320-366-20-3).