Refer to para 4-5 for fuel timing. (1) Raise cab (TM 9-2320-366-10-1). (2) Remove valve cover (TM 9-2320-366-20-3). (3) Position master power switch to on (TM 9-2320-366-10-1). (4) If fuel linkage does not engage when ignition is turned on, go to step 4 of this fault. (5) Position master power switch to off (TM 9-2320-366-10-1). TM 9-2320-366-34-1 Change 1 2-66.13